Page 82 - JCAU-5-1
P. 82

Journal of Chinese
            Architecture and Urbanism                                       Green renovation technology for rural buildings


























































                         Name of the   Thermal resistance  Thermal inertness  Solar radiation   Heat transfer
                         structure   (R) (m k)/W    index         absorption coefficient  coefficient
                                          2
                                                    D=R*S                         W/(m  K)
                                                                                      2
                         Before renovation
                          External walls  0.207         2.300           0.77            2.73
                          Roofing         0.090         1.431           0.74            3.99
                         After renovation
                          External walls  0.546         2.804           0.75            1.34
                          Roofing         0.973         2.983           0.75            0.88
            Figure 6. Comparison of envelope structure and thermal performance indicators before and after renovation. Source: Drawing by the author.

               The  area of  natural  light coefficient  2.0%  of  the   dining room, is sufficient after the renovation, while
               residential building before the renovation is large,   the distribution of light is more even.
               and the indoor light is dim, while the natural light   (iii) The heat insulation performance of the envelope
               coefficient of the public space, such as living room and   structure is obviously improved



            Volume 5 Issue 1 (2023)                         9                         https://doi.org/10.36922/jcau.404