Page 44 - TD-2-3
P. 44
Tumor Discovery Surgical implantation of malignant cells
implantation may require up to 2 – 3 million cells. The References
most robust evidence of implantation of tumor cells along 1. Gerster AG, 1885, On the Surgical Dissemination of Cancer.
needle tracts is in the core biopsy needles from breast New York: New York Surgical Society. p98–109.
cancers, but with a measly incidence rate of implantation
measuring at 0.9%. However, fine needle aspirations are 2. Lack LH, 1896, A contribution to the operative treatment
considered oncologically safe procedures with very low of malignant disease of the larynx,with special reference
rates of implantation and tract recurrences. Multiple to the danger of cancerous wound infection. Lancet,
studies have demonstrated the presence of malignant cells 147: 1638–1641.
in wound washings and wound drainage fluid but these 3. Moher D, Liberati A, Tetzlaff J, et al., 2010, Prefered
studies failed to detect a significant increase in local or reporting items for systematic reviews and meta-analyses:
cutaneous recurrences due to their presence. Although The PRISMA statement. Int J Surg, 8: 336–341.
viable intraperitoneal tumor cells have been detected and https://doi.org/10.1016/j.ijsu.2010.02.007
found to cause intraperitoneal recurrences, the EVOCAPE 4. Ryall C, 1907, Cancer infection and cancer recurrence:
2 prospective study failed to establish it as an independent A danger to avoid in cancer operations. Lancet,
predictor of local recurrence. Laparoscopic surgery of 170: 1311–1316.
intraperitoneal tumors is generally regarded as one of the
factors contributing to port site recurrences, but poor surgical 5. Cole WH, Roberts S, Watne A, et al., 1958, The dissemination
technique leading to excessive tumor handling remains the of cancer cells. Bull New York Acad Med, 34(3): 163–183.
most probable cause. In addition, peritoneal implantation 6. Fortner JG, Lawrence W, 1960, Implantation of gastric
of benign myomas and accidental leiomyosarcoma has cancer in abdominal wounds. Ann Surg, 152(5): 789–794.
become a clinically known fact; therefore, appropriate https://doi.org/10.1097/00000658-196011000-00003
precautions must be taken if intraperitoneal morcellation is
involved as part of the treatment. At present, lavage of the 7. Haverback CZ, Smith RR, 1959, Transplantation of tumour
surgery site with distilled water is the most effective method by suture thread and its prevention: An experimental study.
Cancer, 12(5): 1029–1042.
to prevent the implantation of malignant cells.
https://doi.org/10.1002/1097-0142(195909/10)12:5<1029::aid-
Acknowledgments cncr2820120524>3.0.co;2-q
None. 8. The transfer of tumor cells by the surgical knife, 1937, N Engl
J Med, 216(13): 570.
Funding 9. Thomas CGJ, 1961, Tumor cell contamination of the surgical
None. wound: Experimental and clinical observations. Ann Surg,
153(5): 697–704.
Conflict of interest https://doi.org/10.1097/00000658-196105000-00008
The authors declare that they have no conflict of interest 10. Southam CM, Brunshwig A, 1961, Quantitative studies of
to declare. autotransplantation of human cancer. Cancer, 14: 971–978.
Author contributions 11. Clarke BG, Leadbetter WF, Campbell JS, 1953, Implantation
of cancer of the prostate in site of perineal needle biopsy:
Conceptualization: Ajay Vidyarthi Report of a case. J Urol, 70(6): 937–939.
Writing – original draft: Ajay Vidyarthi, Shruti Khemka, https://doi.org/10.1016/S0022-5347(17)68008-X
Vinay Venkataramu
Writing – review and editing: Kunal Ranjan, Pritesh Rajeev 12. Glasgow BJ, Brown HH, Zargoza AM, et al., 1988,
Singh Quantitation of tumor seeding from fine needle aspiration
of ocular melanomas. Am J Ophthalmol, 105(5): 538–546.
Ethics approval and consent to participate https://doi.org/10.1016/0002-9394(88)90248-6
Not applicable. 13. Mighell AJ, High AS, 1998, Histological identification
of carcinoma in 21 gauge needle tracks after fine needle
Consent for publication aspiration biopsy ofhead and neck carcinoma. J Clin Pathol,
Not applicable. 51: 241–243.
https://doi.org/10.1136/jcp.51.3.241
Availability of data
14. Smith EH, 1991, Complications of percutaneous abdominal
Not applicable. fine-needle biopsy. Radiology, 178(1): 253–258.
Volume 2 Issue 3 (2023) 8 https://doi.org/10.36922/td.1411

