Page 19 - ARNM-2-2
P. 19

Advances in Radiotherapy
            & Nuclear Medicine                                                        CFR-PEEK: A systematic review



               Clin Neurosci. 2020;75:106-111.                    instrumentation with multimodal intraoperative imaging in
                                                                  spinal oncology. Sci Rep. 2022;12(1):15816.
               doi: 10.1016/j.jocn.2020.03.013
                                                                  doi: 10.1038/s41598-022-20222-7
            6.   Shen FH, Gasbarrini A, Lui DF, Reynolds J, Capua J, Boriani S.
               Integrated custom composite polyetheretherketone/carbon   15.  Boriani S, Tedesco G, Ming L, et al. Carbon-fiber-reinforced
               fiber (PEEK/CF) vertebral body replacement (VBR) in   PEEK fixation system in the treatment of spine tumors:
               the treatment of bone tumors of the spine: A preliminary   A preliminary report. Eur Spine J. 2018;27(4):874-881.
               report from  a multicenter  study.  Spine  (Phila Pa 1976).      doi: 10.1007/s00586-017-5258-5
               2022;47(3):252-260.
                                                               16.  Alvarez-Breckenridge C, de Almeida R, Haider A,  et al.
               doi: 10.1097/BRS.0000000000004177
                                                                  Carbon fiber-reinforced polyetheretherketone spinal
            7.   Thureau S, Marchesi V, Vieillard MH,  et al. Efficacy of   implants for treatment of spinal tumors: Perceived
               extracranial stereotactic body radiation therapy (SBRT)   advantages and limitations. Neurospine. 2023;20(1):317-326.
               added to standard treatment in patients with solid tumors
               (breast, prostate and non-small cell lung cancer) with up to      doi: 10.14245/ns.2244920.460
               3 bone-only metastases: Study protocol for a randomised   17.  Adler D, Akbar M, Spicher A, Goerke SA, Schmoelz W.
               phase III trial (STEREO-OS). BMC Cancer. 2021;21(1):117.  Biomechanical study of a novel, expandable, non-metallic
                                                                  and  radiolucent  CF/PEEK  vertebral  body  replacement
               doi: 10.1186/s12885-021-07828-2
                                                                  (VBR). Materials (Basel). 2019;12(17):2732.
            8.   Redmond KJ,  Lo  SS,  Fisher  C, Sahgal  A. Postoperative      doi: 10.3390/ma12172732
               stereotactic body radiation therapy (SBRT) for spine
               metastases: A critical review to guide practice. Int J Radiat   18.  Kabir SMR, Alabi J, Rezajooi K, Casey ATH. Anterior
               Oncol Biol Phys. 2016;95(5):1414-1428.             cervical corpectomy: Review and comparison of results
                                                                  using  titanium  mesh  cages  and  carbon  fibre  reinforced
               doi: 10.1016/j.ijrobp.2016.03.027
                                                                  polymer cages. Br J Neurosurg. 2010;24(5):542-546.
            9.   Ringel F, Ryang YM, Kirschke JS, et al. Radiolucent carbon
               fiber-reinforced pedicle screws for treatment of spinal      doi: 10.3109/02688697.2010.503819
               tumors:  Advantages  for radiation  planning  and follow-up   19.  Scholes SC, Unsworth A. Wear studies on the likely
               imaging. World Neurosurg. 2017;105:294-301.        performance  of  CFR-PEEK/CoCrMo  for  use  as
                                                                  artificial joint bearing materials.  J  Mater Sci Mater Med.
               doi: 10.1016/j.wneu.2017.04.091
                                                                  2009;20(1):163-170.
            10.  Joerger AK, Seitz S, Lange N,  et al. CFR-PEEK pedicle      doi: 10.1007/s10856-008-3558-3
               screw instrumentation for spinal neoplasms: A  single
               center experience on safety and efficacy.  Cancers (Basel).   20.  Georgiou KR, Scherer MA, Fan CM,  et al. Methotrexate
               2022;14(21):5275.                                  chemotherapy  reduces  osteogenesis  but  increases
                                                                  adipogenic  potential  in the bone  marrow.  J  Cell  Physiol.
               doi: 10.3390/cancers14215275
                                                                  2012;227(3):909-918.
            11.  Neal MT, Richards AE, Curley KL,  et al. Carbon fiber-
               reinforced PEEK instrumentation in the spinal oncology      doi: 10.1002/jcp.22807
               population: A retrospective series demonstrating technique,   21.  Itshayek E, Cohen JE, Yamada Y, et al. Timing of stereotactic
               feasibility, and clinical outcomes.  Neurosurg Focus.   radiosurgery and surgery and wound healing in patients
               2021;50(5):E13.                                    with spinal tumors: A systematic review and expert opinions.
                                                                  Neurol Res. 2014;36(6):510-523.
               doi: 10.3171/2021.2.FOCUS20995
                                                                  doi: 10.1179/1743132814Y.0000000380
            12.  Wagner A, Haag E, Joerger AK, et al. Cement-augmented
               carbon fiber-reinforced pedicle screw instrumentation for   22.  Sugimoto M, Takahashi S, Toguchida J, Kotoura Y,
               spinal metastases: Safety and efficacy.  World  Neurosurg.   Shibamoto Y, Yamamuro T. Changes in bone after high-dose
               2021;154:e536-e546.                                irradiation. Biomechanics and histomorphology.  J  Bone
                                                                  Joint Surg Br. 1991;73(3):492-497.
               doi: 10.1016/j.wneu.2021.07.092
                                                                  doi: 10.1302/0301-620X.73B3.1670456
            13.  Tedesco G, Gasbarrini A, Bandiera S, Ghermandi R,
               Boriani  S. Composite PEEK/Carbon fiber implants can   23.  Poel R, Belosi F, Albertini F, et al. Assessing the advantages
               increase the effectiveness of radiotherapy in the management   of CFR-PEEK  over titanium  spinal  stabilization implants
               of spine tumors. J Spine Surg. 2017;3(3):323-329.  in proton therapy-a phantom study.  Phys Med Biol.
                                                                  2020;65(24):245031.
               doi: 10.21037/jss.2017.06.20
                                                                  doi: 10.1088/1361-6560/ab8ba0
            14.  Hubertus V, Wessels L, Früh A, et al. Navigation accuracy
               and  assessability  of  carbon  fiber-reinforced  PEEK   24.  Depauw N, Pursley J, Lozano-Calderon SA, Patel CG.


            Volume 2 Issue 2 (2024)                         11                             doi: 10.36922/arnm.3130
   14   15   16   17   18   19   20   21   22   23   24