Page 58 - ARNM-2-2
P. 58
Advances in Radiotherapy
& Nuclear Medicine PET and Compton Camera CZT based system
15. Beekman FJ, Kamphuis C, Koustoulidou S, Ramakers RM, 26. Llosá G, Rafecas M. Hybrid PET/Compton-camera
Goorden MC. Positron range-free and multi-isotope imaging: An imager for the next generation. Eur Phys J Plus.
tomography of positron emitters. Phys Med Biol. 2021; 2023;138(3):214.
66(6):065011.
doi: 10.1140/epjp/s13360-023-03805-9
doi: 10.1088/1361-6560/abe5fc
27. Parajuli RK, Sakai M, Parajuli R, Tashiro M. Development
16. Pratt EC, Lopez-Montes A, Volpe A, et al. Simultaneous and applications of compton camera-a review. Sensors
quantitative imaging of two PET radiotracers via the (Basel). 2022;22(19):7374.
detection of positron-electron annihilation and prompt
gamma emissions. Nat Biomed Eng. 2023;7(8):1028-1039. doi: 10.3390/s22197374
28. Abbaszadeh S, Gu Y, Sikora U, Levin CS. First Acquisition
doi: 10.1038/s41551-023-01060-y
of Data from a Prototype 3-D Position Sensitive CZT PET
17. Severin GW, Engle JW, Nickles RJ, Barnhart TE. 89Zr System. In: 2014 IEEE Nuclear Science Symposium and
radiochemistry for positron emission tomography. Med Medical Imaging Conference (NSS/MIC); 2014. p. 1-2.
Chem. 2011;7(5):389-394.
doi: 10.1109/NSSMIC.2014.7430998
doi: 10.2174/157340611796799186
29. Abbaszadeh S, Gu Y, Reynolds PD, Levin CS. Characterization
18. Deri MA, Zeglis BM, Francesconi LC, Lewis JS. PET imaging of a sub-assembly of 3D position sensitive cadmium zinc
with Zr: From radiochemistry to the clinic. Nucl Med Biol. telluride detectors and electronics from a sub-millimeter
89
2013;40(1):3-14. resolution PET system. Phys Med Biol. 2016;61(18):6733.
doi: 10.1016/j.nucmedbio.2012.08.004 doi: 10.1088/0031-9155/61/18/6733
19. Yoon JK, Park BN, Ryu EK, An YS, Lee SJ. Current perspectives 30. Abbaszadeh S, Levin CS. New-generation small animal
on Zr-PET imaging. Int J Mol Sci. 2020;21(12):4309. positron emission tomography system for molecular
89
doi: 10.3390/ijms21124309 imaging. J Med Imaging (Bellingham). 2017;4(1):011008.
89
20. Sarcan ET, Silindir-Gunay M, Ozer AY, Hartman N. Zr as doi: 10.1117/1.JMI.4.1.011008
a promising radionuclide and it’s applications for effective 31. Abbaszadeh S, Chinn G, Levin CS. Positioning true
cancer imaging. J Radioanal Nucl Chem. 2021;330(1):15-28. coincidences that undergo inter-and intra-crystal scatter
doi: 10.1007/s10967-021-07928-0 for a sub-mm resolution cadmium zinc telluride-based PET
system. Phys Med Biol. 2018;63(2):025012.
21. Lee YJ, Van den Berg NS, Duan H, et al. 89Zr-panitumumab
combined with 18F-FDG PET improves detection and doi: 10.1088/1361-6560/aa9a2b
staging of head and neck squamous cell carcinoma. Clin 32. Li M, Abbaszadeh S. Influence of channel configuration on
Cancer Res. 2022;28(20):4425-4434. bandwidth of cadmium zinc telluride detector with a cross-
doi: 10.1158/1078-0432.CCR-22-0094 strip pattern. Radiat Phys Chem. 2019;155:213-216.
22. Knight JC, Mosley MJ, Kersemans V, et al. Dual-isotope doi: 10.1016/j.radphyschem.2018.04.015
imaging allows in vivo immunohistochemistry using 33. Vernekohl D, Abbaszadeh S, Gu Y, Levin CS. Robust
radiolabelled antibodies in tumours. Nucl Med Biol. detector calibration for a novel PET system based on cross-
2019;70:14-22. strip CZT detectors. IEEE Trans Radiat Plasma Med Sci.
doi: 10.1016/j.nucmedbio.2019.01.010 2019;3(6):626-633.
23. Yoshida E, Tashima H, Nagatsu K, et al. Whole gamma doi: 10.1109/TRPMS.2018.2878574
imaging: A new concept of PET combined with Compton 34. Li M, Yockey B, Abbaszadeh S. Design study of a dedicated
imaging. Phys Med Biol. 2020;65(12):125013. head and neck cancer PET system. IEEE Trans Radiat
doi: 10.1088/1361-6560/ab8e89 Plasma Med Sci. 2020;4(4):489-497.
24. Tashima H, Yoshida E, Wakizaka H, et al. 3D Compton doi: 10.1109/TRPMS.2020.2964293
image reconstruction method for whole gamma imaging. 35. Li M, Wang Y, Abbaszadeh S. Development and initial
Phys Med Biol. 2020;65(22):225038. characterization of a high-resolution PET detector module
doi: 10.1088/1361-6560/abb92e with DOI. Biomed Phys Eng Express. 2020;6(6):065020.
25. Giovagnoli D, Bousse A, Beaupere N, et al. A pseudo-TOF doi: 10.1088/2057-1976/abbd4f
image reconstruction approach for three-gamma small 36. Farahmandzadeh M, Abbaszadeh S. A machine learning
animal imaging. IEEE Trans Radiat Plasma Med Sci. approach for identifying correct sequence of multiple
2021;5(6):826-834.
interaction photon event in PET systems. J Nucl Med.
doi: 10.1109/TRPMS.2020.3046409 2020;61(Suppl 1):1514-1514.
Volume 2 Issue 2 (2024) 12 doi: 10.36922/arnm.3330

