Page 230 - IJB-10-6
P. 230

International Journal of Bioprinting                             3DP Ta buttress in DDH shelf acetabuloplasty




            3.   Holm AG, Reikerås O, Terjesen T. Long-term results of a      doi: 10.1302/0301-620x.84b5.12732
               modified Spitzy shelf operation for residual hip dysplasia   14.  Summers BN, Turner A, Wynn-Jones CH. The shelf operation
               and subluxation. A fifty year follow-up study of fifty  six   in the management of late presentation of congenital hip
               children and young adults. Int Orthop. 2017;41(2):415-421.  dysplasia. J Bone Joint Surg Br. 1988;70(1):63-68.
               doi: 10.1007/s00264-016-3286-0                     doi: 10.1302/0301-620X.70B1.3276702
            4.   Christen P, Ito K, Galis F, van Rietbergen B. Determination
               of hip-joint loading patterns of living and extinct mammals   15.  Ramdhan  Ibrahim MA,  Kamegaya M,  Morita M,  Saisu
               using an inverse Wolff’s law approach.  Biomech Model   T,  Kakizaki J,  Oikawa Y.  Radiological  results  of  Shelf
               Mechanobiol. 2015;14(2):427-432.                   acetabuloplasty in adolescent hip dysplasia with aspherical
               doi: 10.1007/s10237-014-0602-8                     femoral head: how to get an ideal placement of the Shelf
            5.   Yang S,  Zusman N, Lieberman E, Goldstein  RY.   graft. J Pediatr Orthop B. 2020;29(3):261-267.
               Developmental  dysplasia  of  the  hip.  Pediatrics.      doi: 10.1097/BPB.0000000000000681
               2019;143(1):e20181147.                          16.  Okolie O, Stachurek I, Kandasubramanian B, Njuguna J.
               doi: 10.1542/peds.2018-1147                        3D printing for hip implant applications: a review. Polymers
            6.   Schmitz MR, Murtha AS, Clohisy JC; ANCHOR Study   (Basel). 2020;12(11):2682.
               Group. Developmental dysplasia of the hip in adolescents      doi: 10.3390/polym12112682
               and young adults. J Am Acad Orthop Surg. 2020;28(3):91-101.  17.  Jing Z, Zhang T, Xiu P, et al. Functionalization of 3D-printed
               doi: 10.5435/JAAOS-D-18-00533
                                                                  titanium  alloy orthopedic  implants:  a  literature review.
            7.   Ganz R, Klaue K, Vinh TS, Mast JW. A new periacetabular   Biomed Mater. 2020;15(5):052003.
               osteotomy for the treatment of hip dysplasias. Technique and      doi: 10.1088/1748-605X/ab9078
               preliminary results. Clin Orthop Relat Res. 1988;(232):26-36.
                                                               18.  Kumar A, Nune KC, Misra RDK. Design and biological
            8.   Tan JHI, Tan SHS, Rajoo MS, Lim AKS, Hui JH. Hip   functionality of a novel hybrid Ti-6Al-4V/hydrogel system
               survivorship following the Bernese periacetabular   for reconstruction of bone defects. J Tissue Eng Regen Med.
               osteotomy for the treatment of acetabular dysplasia: a   2018;12(4):1133-1144.
               systematic review and meta-analysis. Orthop Traumatol Surg      doi: 10.1002/term.2614
               Res. 2022;108(4):103283.                        19.  Barui S, Chatterjee S, Mandal S, Kumar A, Basu B.
               doi: 10.1016/j.otsr.2022.103283                    Microstructure and compression properties of 3D powder
            9.   Suzuki M, Kinoshita K, Sakamoto T, Seo H, Yoshimura I,   printed Ti-6Al-4V scaffolds with designed porosity:
               Yamamoto T. Short-term outcomes of curved periacetabular   Experimental and computational analysis. Mater Sci Eng C
               osteotomy and factors influencing patient dissatisfaction.    Mater Biol Appl. 2017;70(Pt 1):812-823.
               J Hip Preserv Surg. 2023;10(1):17-23.              doi: 10.1016/j.msec.2016.09.040
               doi: 10.1093/jhps/hnac054
                                                               20.  Borland WS, Bhattacharya R, Holland JP, Brewster NT.
            10.  Abraham CL, Knight SJ, Peters CL, Weiss JA, Anderson   Use  of  porous  trabecular  metal  augments  with  impaction
               AE. Patient-specific chondrolabral contact mechanics in   bone grafting in management of acetabular bone loss. Acta
               patients with acetabular dysplasia following treatment   Orthop. 2012;83(4):347-352.
               with  peri-acetabular  osteotomy.  Osteoarthritis Cartilage.      doi: 10.3109/17453674.2012.718518
               2017;25(5):676-684.
               doi: 10.1016/j.joca.2016.11.016                 21.  Han  Y,  Chen  D,  Sun  J,  Zhang  Y,  Xu  K.  UV-enhanced
                                                                  bioactivity and cell response of micro-arc oxidized titania
            11.  Matsui M, Masuhara K, Nakata K, Nishii T, Sugano N, Ochi
               T. Early deterioration after modified rotational acetabular   coatings. Acta Biomater. 2008;4(5):1518-1529.
               osteotomy for the dysplastic hip.  J Bone Joint Surg Br.      doi: 10.1016/j.actbio.2008.03.005
               1997;79(2):220-224.                             22.   Huang T, Wang H, Zhang Z, Feng K, Xiang L. Incorporation of
               doi: 10.1302/0301-620x.79b2.7202                   inorganic elements onto titanium-based implant surfaces by
                                                                  one-step plasma electrolytic oxidation: an efficient method to
            12.  Fawzy E, Mandellos G,  De Steiger  R, McLardy-Smith
               P, Benson MK, Murray D. Is there a place for shelf   enhance osteogenesis. Biomater Sci. 2022;10(23):6656-6674.
               acetabuloplasty in the management of adult acetabular      doi: 10.1039/d2bm00818a
               dysplasia?  A  survivorship  study.  J Bone Joint Surg Br.   23.  Levine B, Della Valle CJ, Jacobs JJ. Applications of porous
               2005;87(9):1197-1202.                              tantalum in total hip arthroplasty. J Am Acad Orthop Surg.
               doi: 10.1302/0301-620X.87B9.15884                  2006;14(12):646-655.
                                                                  doi: 10.5435/00124635-200611000-00008
            13.  Nishimatsu H, Iida H, Kawanabe K, Tamura J, Nakamura
               T. The modified Spitzy shelf operation for patients with   24.  Carraro F, Bagno A. Tantalum as trabecular metal for
               dysplasia of the hip. A 24-year follow-up study. J Bone Joint   endosseous  implantable  applications.  Biomimetics  (Basel).
               Surg Br. 2002;84(5):647-652.                       2023;8(1):49.




            Volume 10 Issue 6 (2024)                       222                                doi: 10.36922/ijb.4074
   225   226   227   228   229   230   231   232   233   234   235