Page 135 - IJB-7-4
P. 135

Li, et al
               Pressure Ulcers: SECURE Prevention. J Wound Care, 29:S1-52.  14.  Zhuang Z, Bergman M, Brochu E,  et al.,  2016, Temporal
           3.   Gosch, M.E., Shaffer RE, Eagan AE, et al., 2013, B95: A New   Changes  in  Filtering-facepiece  Respirator  Fit.  J  Occup
               Respirator for Health Care Personnel. Am J Infect Control,   Environ Hyg, 13:265-74.
               41:1224-30.                                     15.  Sandkovsky U, Schwedhelm M, Grayer S, et al., 2017, Small
           4.   O’Kelly E, Arora A, Pirog S, et al., 2021, Comparing the Fit   changes make a big difference in the fit of N95 respirators.
               of N95, KN95, Surgical, and Cloth Face Masks and Assessing   Open Forum Infect Dis, 4:S166.
               the Accuracy of Fit Checking. PLoS One, 16:e0245688.     https://doi.org/10.1093/ofid/ofx163.292
               https://doi.org/10.1371/journal.pone.0245688    16.  Roebuck JA, 1995, Anthropometric Methods: Designing to
           5.   Pompeii LA, Kraft CS, Brownsword EA. et al. Training and   Fit the Human Body. In: Human Factors and Ergonomics
               Fit Testing of Health Care Personnel for Reusable Elastomeric   Society. Santa Monica, California: Humanoid Factors and
               Half-Mask Respirators Compared  With Disposable N95   Ergonomics Society.
               Respirators. JAMA, 323:1849-52.                     https://doi.org/10.1177/106480469500300309
               https://doi.org/10.1001/jama.2020.4806          17.  Pheasant S, 2014, Bodyspace: Anthropometry, Ergonomics
           6.   Han DH, Choi KL, 2003, Facial Dimensions and Predictors of   and the Design of Work: Anthropometry, Ergonomics and the
               Fit for Half-mask Respirators in Koreans. Aiha J, 64:815-22.  Design of Work. Boca Raton, Florida: CRC Press.
               https://doi.org/10.1080/15428110308984877           https://doi.org/10.1201/9781482272420
           7.   McMahon E, Wada K, Dufresne A, 2008, Implementing Fit   18.  Chen W, Zhuang Z, Benson S, et al., 2009, New Respirator
               Testing  for N95 Filtering  Facepiece  Respirators:  Practical   Fit  Test Panels Representing the Current Chinese Civilian
               Information from a Large Cohort of Hospital Workers. Am J   Workers. Ann Occup Hyg, 53:297-305.
               Infect Control, 36:298-300.                         https://doi.org/10.1093/annhyg/men089
               https://doi.org/10.1016/j.ajic.2007.10.014      19.  Hack A, Hyatt EC, Held BJ, et al., 1973, Selection of Respirator
           8.   Ascott A, Crowest P, de Sausmarez E, et al., 2020, Respiratory   Test Panels Representative of US Adult Facial Sizes. New
               Personal Protective Equipment  for Healthcare  Workers:   Mexico: Los Alamos Scientific Lab., N. Mex, (USA).
               Impact of Sex Differences on Respirator Fit Test Results. Br      https://doi.org/10.2172/4335046
               J Anaesth, 126:e48-e49.                         20.  Zhuang  Z,  Bradtmiller  B,  2005,  Head-and-Face
               https://doi.org/10.1016/j.bja.2020.10.016           Anthropometric  Survey of US Respirator  Users.  J  Occup
           9.   Regli  A,  Sommerfield  A,  von  Ungernd.org/10.1  B,  2021,   Environ Hyg, 2:567-576.
               The Role of Fit Testing N95/FFP2/FFP3 Masks: A Narrative      https://doi.org/10.1080/15459620500324727
               Review. Anaesthesia, 76:91-100.                 21.  Zhuang Z, Landsittel  D, Benson S,  et al., 2010, Facial
               https://doi.org/10.1111/anae.15261                  Anthropometric  Differences  among  Gender,  Ethnicity,  and
           10.  Lam S, Lee  JK,  Yau SY,  et al., 2011, Sensitivity  and   Age Groups. Ann Occup Hyg, 54:391-402.
               Specificity of the User-seal-check in Determining the Fit of   22.  Kim H, Han DH, Roh YM, et al., 2003, Facial Anthropometric
               N95 Respirators. J Hosp Infect, 77:252-256.         Dimensions of Koreans and their Associations with Fit of
               https://doi.org/10.1016/j.jhin.2010.09.034          Quarter-mask Respirators. Ind Health, 41:8-18.
           11.  Yu Y, Jiang L, Zhuang Z, et al. 2014, Fitting Characteristics      https://doi.org/10.2486/indhealth.41.8
               of N95 Filtering-facepiece Respirators Used Widely in China.   23.  Du L, Zhuang Z, Guan H,  et al., 2008, Head-and-face
               PLoS One, 9:e85299.                                 Anthropometric  Survey of Chinese  Workers.  Ann Occup
               https://doi.org/10.1371/journal.pone.0085299        Hyg, 52:773-782.
           12.  Spies  A,  Wilson  KS, Ferrie  R, 2011, Respirator  Fit  of a   24.  Yang L, Shen H, Wu G, 2007, Racial Differences in Respirator
               Medium Mask on a Group of South  Africans:  A  Cross-  Fit Testing: A Pilot Study of Whether American Fit Panels are
               sectional Study. Environ Health, 10:1-7.            Representative of Chinese Faces. Ann Occup Hyg, 51:415-421.
               https://doi.org/10.1186/1476-069x-10-17             https://doi.org/10.1093/annhyg/mem005
           13.  Wilkinson IJ, Pisaniello D, Ahmad J, et al., 2010, Evaluation   25.  Tuck  CJ,  Hague  RJ,  Ruffo  M,  et al., 2008, Rapid
               of a Large-scale Quantitative Respirator-fit Testing Program   Manufacturing  Facilitated  Customization.  Int  J  Comput
               for Healthcare Workers: Survey Results. Infect Control Hosp   Integr Manufact, 21:245-258.
               Epidemiol, 31:918-25.                               https://doi.org/10.1080/09511920701216238
               https://doi.org/10.1086/655460                  26.  Tan HW, An J, Chua CK, et al., 2019, Metallic Nanoparticle Inks

                                       International Journal of Bioprinting (2021)–Volume 7, Issue 4       131
   130   131   132   133   134   135   136   137   138   139   140