Page 105 - IJOCTA-15-4
P. 105

Advanced frequency control strategy for power systems with high renewable energy penetration

                Energy Rev. 2017;80:1321-1344.                    Minneapolis, MN, USA; 2010:1-6.
                https://doi.org/10.1016/j.rser.2017.05.095        https://doi.org/10.1109/pes.2010.5590220
             28. Okafor CE, Folly KA. Optimal placement of Bess  39. Andersson G, Donalek P, Farmer R, et al. Causes
                in a power system network for frequency support   of the 2003 major grid blackouts in North Amer-
                during contingency. Energy Rep. 2023;10:3681-     ica and Europe, and recommended means to im-
                3695.                                             prove system dynamic performance. IEEE Trans
                https://doi.org/10.1016/j.egyr.2023.10.017        Power Syst. 2005;20(4):1922-1928.
             29. Morren J, Pierik J, De Haan SW. Inertial re-     https://doi.org/10.1109/tpwrs.2005.857942
                sponse of variable speed wind turbines. Electric  40. No. 25/2016/TT-BCT Regulations on Elec-
                Power Syst Res. 2006;76(11):980-987.              tricity  Transmission  System.  Ministry  of
                https://doi.org/10.20944/preprints201609.0118.v1  Industry  and  Trade  Circular,  Viet  Nam.
             30. MathWorks.               Battery-Implement       November    30,   2016,   Available  online:
                Generic     Battery     Model.      [Online].     https://thuvienphapluat.vn/van-ban/Thuong-
                https://www.mathworks.com/help/sps/powersys       mai/Circular-25-2016-TT-BCT-regulations-
                /ref/battery.html                                 electricity-transmission-system-339051.aspx.
             31. Farrokhabadi M, K¨onig S, Ca˜nizares CA, Bhat-  41. Choi WY, Kook KS, Yu GR. Control strategy
                tacharya K, Leibfried T. Battery energy stor-     of BESS for providing both virtual inertia and
                age system models for microgrid stability analysis  primary frequency response in the Korean Power
                and dynamic simulation. IEEE Trans Power Syst.    System. Energies. 2019;12(21):4060.
                2017;33(2):2301-2312.                             https://doi.org/10.3390/en12214060
                https://doi.org/10.1109/TPWRS.2017.2740163
             32. Wang Y, Ren B. Fault ride-through enhance-
                ment for grid-tied PV systems with robust con-
                trol. IEEE Trans Ind Electron. 2017;65(3):2302-  Tran Viet Thanh is currently working at Power
                2312.                                         Engineering Consulting Joint Stock Company 4
                https://doi.org/10.1109/TIE.2017.2740858      (PECC4), Nha Trang, Khanh Hoa, Vietnam, and
             33. Akca H, AKTAS¸ A. Examination and experimen-  work as Deputy Director of the Department of Re-
                tal comparison of DC/DC Buck converter topolo-  search and Development of PECC4. He completed
                gies used in wireless electric vehicle charging ap-  his B.Sc. and M.Sc. Engineering degrees in The
                plications. Int J Optimiz Control: Theor Appl.  University of Danang - University of Science and
                2024;14(2):81-89.
                                                              Technology, Da Nang, Vietnam. Currently, he is
                https://doi.org/10.11121/ijocta.1503
                                                              pursuing a Ph.D. degree in electrical engineering
             34. Yan G, Liu D, Li J, Mu G. A cost accounting
                                                              at the University of Danang. His main research
                method of the Li-ion battery energy storage sys-
                                                              directions include power system stability and cal-
                tem for frequency regulation considering the effect
                                                              culation, renewable energy applications and en-
                of life degradation. Prot Control Modern Power
                Syst. 2018;3(1):1-9.                          ergy storage equipment design.
                https://doi.org/10.1186/s41601-018-0076-2        http://orcid.org/0009-0002-9274-9176
             35. Van Dai L, Hong Thanh P. A feasible MPPT algo-
                rithm for the DC/DC boost converter: an applied  Le Cao Quyen has been at the University of
                case for stand-alone solar photovoltaic systems.  Danang - University of Science and Technology,
                Int J Elect Comput Eng Syst. 2023;14(6):713-724.
                https://doi.org/10.32985/ijeces.14.6.11       Da Nang, Vietnam since 2012. He is currently
             36. Van Dai L, Li X, Dong TLT, Cao Quyen L.      working as the Doctor of the Faculty of Electrical
                An innovative control strategy to improve the  Engineering at the University of Danang. He is
                fault ride-through capability of DFIGs based  also the current Chairman of directors of Power
                on wind energy conversion systems. Energies.  Engineering Consulting Joint Stock Company 4
                2016;9(2):69.                                 (PECC4), Nha Trang, Khanh Hoa, Vietnam. He
                https://doi.org/10.3390/en9020069             has rich and deep experience in power network
             37. Thanh TV, Viet DT, Hieu NT. A solution to en-  system both in traditional and smart grids, as
                hance operational effectiveness of the renewable  well as in project planning and management. He
                energy sources and power system transmission
                                                              received his B.Sc. and M.Sc. Engineering de-
                lines in Vietnam. In: Proc. of 6th International
                                                              grees from HCM Bach Khoa University, Viet-
                Conference on Green Technology and Sustainable
                                                              nam. He completed his Ph.D. at the University
                Development (GTSD), Nha Trang City, Vietnam;
                                                              of Danang. He has conducted research, provided
                2022:693-699.
                https://doi.org/10.1109/gtsd54989.2022.9989150  electrical utilities consultancy, and published over
             38. Mahmud M, Hossain M, Pota H. Investigation   twenty publications on his area of expertise. His
                of critical parameters for power systems stabil-  research interests are system stability, electromag-
                ity with dynamic loads. In: Proc. of Interna-  netic transient and renewable energy.
                tional Conference IEEE PES General Meeting,      https://orcid.org/0009-0001-6760-0495
                                                           647
   100   101   102   103   104   105   106   107   108   109   110