Page 625 - IJB-10-3
P. 625

International Journal of Bioprinting                       Wireless module system applied on 3D-printed implant




               doi: 10.1016/j.oooo.2015.10.005                 15.  Bedogni A, Bettini G, Bedogni G, et al. Safety of boneless
                                                                  reconstruction of the mandible with a CAD/CAM designed
            9.   Wilkman T, Apajalahti S, Wilkman E, Törnwall J, Lassus
               P. A comparison of bone resorption over time: an analysis   titanium device: the replica cohort study.  Oral Oncol.
               of the free scapular, iliac crest, and fibular microvascular   2021;112:105073.
               flaps in mandibular reconstruction. J Oral Maxillofac Surg.      doi: 10.1016/j.oraloncology.2020.105073
               2017;75(3):616-621.                             16.  Cozzolino F, Apicella D, Wang G, Apicella A, Sorrentino R.
               doi: 10.1016/j.joms.2016.09.009                    Implant-to-bone force transmission: a pilot study for in vivo
            10.  Kawasaki G, Imayama N, Yoshitomi I, Furukawa K,   strain gauge measurement technique. J Mech Behav Biomed
               Umeda M. Clinical study of reconstruction plates used in   Mater. 2019;90:173-181.
               the surgery for mandibular discontinuity defect.  In Vivo.      doi: 10.1016/j.jmbbm.2018.10.014
               2019;33(1):191-194.                             17.  Arami A, Delaloye JR, Rouhani H, Jolles BM, Aminian
               doi: 10.21873/invivo.11458                         K. Knee implant loosening detection: a vibration analysis
            11.  van Kootwijk A, Moosabeiki V, Saldivar MC, et al. Semi-  investigation. Ann Biomed Eng. 2018;46(1):97-107.
               automated digital workflow to design and evaluate patient-     doi: 10.1007/s10439-017-1941-2
               specific mandibular reconstruction implants. J Mech Behav   18.  Seide K, Aljudaibi M, Weinrich N, et al. Telemetric assessment
               Biomed Mater. 2022;132:105291.                     of bone healing with an instrumented internal fixator: a
               doi: 10.1016/j.jmbbm.2022.105291
                                                                  preliminary study. J Bone Joint Surg Br. 2012;94(3):398-404.
            12.  Lin CL, Wang YT, Chang CM, Wu CH, Tsai WH. Design      doi: 10.1302/0301-620X.94B3.27550
               criteria for patient-specific mandibular continuity defect
               reconstructed implant with lightweight structure using   19.  Schupp W, Arzdorf M, Linke B, Gutwald R. Biomechanical
               weighted topology optimization and validated with   testing of different osteosynthesis systems for segmental
               biomechanical fatigue testing. Int J Bioprint. 2022;8(1):437.   resection of the mandible.  J Oral Maxillofac Surg.
               doi: 10.18063/ijb.v8i1.437                         2007;65:924-930.
                                                                  doi: 10.1016/j.joms.2006.06.306
            13.  Li CH, Wu CH, Lin CL. Design of a patient-specific mandible
               reconstruction implant with dental prosthesis for metal 3D   20.  Lin CL,  Wang JC, Chang WJ.  Biomechanical interactions
               printing using integrated weighted topology optimization   in  tooth-implant‐supported  fixed  partial  dentures  with
               and finite element analysis.  J Mech Behav Biomed Mater.   variations in the number of splinted teeth and connector
               2020;105:103700.                                   type: a finite element analysis.  Clin Oral Implants Res.
               doi: 10.1016/j.jmbbm.2020.103700                   2008;19:107–117.
                                                                  doi: 10.1111/j.1600-0501.2007.01363.x
            14.  Subash  P, Nerurkar  SA,  Krishnadas A,  Vinay V,  Iyer S,
               Manju V. Patient specific alloplastic implant reconstruction   21.  Ren R, Spaan J, Jordan A, Shafiro A, Su EP. Novel use of an
               of mandibular defects-safe practice recommendations and   accelerometer to assess load asymmetry over time after hip
               guidelines. J Maxillofac Oral Surg. 2023;22(Suppl 1):28-36.   resurfacing arthroplasty. J Arthroplasty. 2023;38(7S):S58-S64.
               doi: 10.1007/s12663-023-01881-z                    doi: 10.1016/j.arth.2023.04.015






























            Volume 10 Issue 3 (2024)                       617                                doi: 10.36922/ijb.2553
   620   621   622   623   624   625   626   627   628