Page 73 - IJB-7-3
P. 73
Yang, et al.
https://doi.org/10.1002/adfm.201907820 Recording of Cardiac Electrophysiology and Contraction on
67. Kim DS, Jeong YJ, Lee BK, et al., 2017, Piezoresistive Chip. Lab Chip, 17:1732–9.
Sensor-Integrated PDMS Cantilever: A New Class of Device https://doi.org/10.1039/c7lc00210f
for Measuring the Drug-Induced Changes in the Mechanical 77. Tian B, Cohen-Karni T, Qing Q, et al., 2010, Three-
Activity of Cardiomyocytes. Sens Actuators B Chem, Dimensional, Flexible Nanoscale Field-Effect Transistors as
240:566–72. Localized Bioprobes. Science, 329:830–4.
https://doi.org/10.1016/j.snb.2016.08.167 https://doi.org/10.1126/science.1192033
68. Wang L, Dou W, Malhi M, et al., 2018, Microdevice Platform 78. Abbott J, Ye T, Qin L, et al., 2017, CMOS Nanoelectrode
for Continuous Measurement of Contractility, Beating Array for All-Electrical Intracellular Electrophysiological
Rate, and Beating Rhythm of Human-Induced Pluripotent Imaging. Nat Nanotechnol, 12:460–6.
Stem Cell-Cardiomyocytes inside a Controlled Incubator https://doi.org/10.1038/nnano.2017.3
Environment. Acs Appl Mater Interfaces, 10:21173–83. 79. Dai X, Zhou W, Gao T, et al., 2016, Three-Dimensional
https://doi.org/10.1021/acsami.8b05407.s001 Mapping and Regulation of Action Potential Propagation
69. Coln EA, Colon A, Long CJ, et al., 2019, Piezoelectric in Nanoelectronics-Innervated Tissues. Nat Nanotechnol,
bioMEMS Cantilever for Measurement of Muscle Contraction 11:776–82.
and for Actuation of Mechanosensitive Cells. MRS Commun, https://doi.org/10.1038/nnano.2016.96
9:1186–92. 80. Kaneko T, Kojima K, Yasuda K, 2007, An On-Chip
https://doi.org/10.1557/mrc.2019.129 Cardiomyocyte Cell Network Assay for Stable Drug
70. Wang A, Liu Z, Hu M, et al., 2018, Piezoelectric Nanofibrous Screening Regarding Community Effect of Cell Network
Scaffolds as In Vivo Energy Harvesters for Modifying Size. Analyst, 132:892–8.
Fibroblast Alignment and Proliferation in Wound Healing. https://doi.org/10.1039/b704961g
Nano Energy, 43:63–71. 81. Aung A, Bhullar IS, Theprungsirikul J, et al., 2016, 3D
https://doi.org/10.1016/j.nanoen.2017.11.023 Cardiac Mu Tissues Within a Microfluidic Device with Real-
71. Sakamiya M, Fang Y, Mo X, et al., 2020, A Heart-on-a-Chip Time Contractile Stress Readout. Lab Chip, 16:153–62.
Platform for Online Monitoring of Contractile Behavior https://doi.org/10.1039/c5lc00820d
Via Digital Image Processing and Piezoelectric Sensing 82. Mai-Dung N, Tinney JP, Yuan F, et al., 2013, Cardiac Cell
Technique. Med Eng Phys, 75:36–44. Culture Model As a Left Ventricle Mimic for Cardiac Tissue
https://doi.org/10.1016/j.medengphy.2019.10.001 Generation. Anal Chem, 85:8773–9.
72. Lind JU, Yadid M, Perkins I, et al., 2017, Cardiac https://doi.org/10.1021/ac401910d
Microphysiological Devices with Flexible Thin-Film Sensors 83. Chen Y, Chan HN, Michael SA, et al., 2017, A Microfluidic
for Higher-Throughput Drug Screening. Lab Chip, 17: Circulatory System Integrated with Capillary-Assisted
3692–703. Pressure Sensors. Lab Chip, 17:653–62.
https://doi.org/10.1039/c7lc00740j https://doi.org/10.1039/c6lc01427e
73. Kang D, Pikhitsa PV, Choi YW, et al., 2014, Ultrasensitive 84. Savoji H, Mohammadi MH, Rafatian N, et al., 2019,
Mechanical Crack-Based Sensor Inspired by the Spider Cardiovascular Disease Models: A Game Changing Paradigm
Sensory System. Nature, 516:222–6. in Drug Discovery and Screening. Biomaterials, 198:3–26.
https://doi.org/10.1038/nature14002 https://doi.org/10.1016/j.biomaterials.2018.09.036
74. Kim DS, Choi YW, Shanmugasundaram A, et al., 2020, 85. Ren L, Liu W, Wang Y, et al., 2013, Investigation of Hypoxia-
Highly Durable Crack Sensor Integrated with Silicone Induced Myocardial Injury Dynamics in a Tissue Interface
Rubber Cantilever for Measuring Cardiac Contractility. Nat Mimicking Microfluidic Device. Anal Chem, 85:235–44.
Commun, 11:535. https://doi.org/10.1021/ac3025812
https://doi.org/10.1038/s41467-019-14019-y 86. Liu H, Bolonduro OA, Hu N, et al., 2020, Heart-on-a-Chip
75. Kireev D, Seyock S, Lewen J, et al., 2017, Graphene Model with Integrated Extra-and Intracellular Bioelectronics
Multielectrode Arrays as a Versatile Tool for Extracellular for Monitoring Cardiac Electrophysiology under Acute
Measurements. Adv Healthc Mater, 6:1601433. Hypoxia. Nano Lett, 20:2585–93.
https://doi.org/10.1002/adhm.201601433 https://doi.org/10.1021/acs.nanolett.0c00076
76. Qian F, Huang C, Lin YD, et al., 2017, Simultaneous Electrical 87. Martewicz S, Michielin F, Serena E, et al., 2012, Reversible
International Journal of Bioprinting (2021)–Volume 7, Issue 3 69

