Page 114 - IJB-8-2
P. 114
3D-Printing-Assisted EADs for Preventing VUR through DJ Stents
computational simulation was conducted for forward References
and backward urine flows. Consequently, the difference
in the cross-sectional pressure fields of the penta-shaped 1. Pengfei S, Min J, Jie Y, et al., 2011, Use of Ureteral Stent
EAD could expand the canopy membrane along the rib in Extracorporeal Shock Wave Lithotripsy for Upper Urinary
structures of the EAD. For the fabrication of the EADs, 3D Calculi: A Systematic Review and Meta-analysis. J Urol,
printing and casting methods were utilized. The printed 186:1328–35.
PLA mold and die were tailored to create four different https://doi.org/10.1016/j.juro.2011.05.073
umbrella shapes with flexible and biocompatible Ecoflex.
Among the fabricated devices, the penta-shaped EAD 2. Hübner WA, Plas EG, Trigo-Rocha F, et al., 1993, Drainage
showed the best anti-reflux performance compared to and Reflux Characteristics of Antireflux Ureteral Double-J
the other types. The maximum anti-reflux efficiency was Stents. J Endourol, 7:497–9.
observed when the EAD was attached near the bladder- https://doi.org/10.1089/end.1993.7.497
ureter junction, and an approximately 44% decrease in 3. Dyer RB, Chen MY, Zagoria RJ, et al., 2002, Complications
reflux was demonstrated in the ureter line using a voiding of Ureteral Stent Placement. Radiographics, 22:1005–22.
model. In addition, the anti-reflux efficiency did not show
significant changes depending on the number of EADs https://doi.org/10.1148/radiographics.22.5.g02se081005
attached to the DJ stent. Thus, a single EAD sufficed 4. Irani J, Siquier J, Pirès C, et al., 1999, Symptom Characteristics
to minimize reflux of urine with minimal discomfort to and the Development of Tolerance with Time in Patients with
patients. A disadvantage of the FDM-type 3D printer (i.e., Indwelling Double-pigtail Ureteric Stents. BJU Int, 84:276–9.
rough surface with grooved patterns) was intentionally https://doi.org/10.1046/j.1464-410x.1999.00154.x
used for mechanically robust adhesion between the 5. Auge BK, Preminger GM, 2002, Ureteral stents and their use
EAD and DJ stent. Finally, a long-term soaking test in
artificial urine with different pH values was performed in endourology. Curr Opin Urol, 12:217–22.
to demonstrate the safety, mechanical durability, and https://doi.org/10.1097/00042307-200205000-00007
chemical stability of the device in urine for at least 6. Sarier M, Demir M, Duman I, et al., 2017, Evaluation of
4 weeks. Although in vivo and parametric studies on the Ureteral Stent Colonization in Live-Donor Renal Transplant
length, shape, and thickness of the EAD are required Recipients. Transplant Proc, 49:415–9.
to enhance the rectification performance, the findings https://doi.org/10.1016/j.transproceed.2017.01.004
of this study support the use of 3D printing methods to
manufacture various medical devices with flexibility, 7. Sarier M, Seyman D, Tekin S, et al., 2017, Comparision of
biocompatibility, mechanical durability, and chemical Ureteral Stent Colonization Between Deceased and Live Donor
stability for urological applications. Renal Transplant Recipients. Transplant Proc, 49:2082–5.
https://doi.org/10.1016/j.transproceed.2017.09.028
Funding 8. Kim HH, Kim KW, Choi YH, et al., 2020, Numerical
This work was supported by the National Research Analysis of Urine Flow with Multiple Sizes of Double-J
Foundation of Korea (NRF), funded by the Ministry of Stents. Appl Sci, 10:4291.
Science and ICT of the Republic of Korea (No. NRF- https://doi.org/10.3390/app10124291
2021R1C1C1010836).
9. Seymour H, Patel U, 2000, Ureteric Stenting-current Status.
Conflict of interest Semin Intervent Radiol, 17:351–65.
The authors declare that there is no conflict of interest. https://doi.org/10.1055/s-2000-13148
10. Damiano R, Oliva A, Esposito C, et al., 2002, Early and Late
Author contributions Complications of Double Pigtail Ureteral Stent. Urol Int,
J. L. Conceptualization, methodology, formal analysis, 69:136–40.
investigation, data curation, validation, visualization, https://doi.org/10.1159/000065563
writing - original draft, writing - review and editing. J. 11. Leibovici D, Cooper A, Lindner A, et al., 2005, Ureteral
S. Conceptualization, methodology, investigation, data Stents: Morbidity and Impact on Quality of Life. Isr Med
curation, validation, writing - review and editing. J. K. Assoc J, 7:491–4.
J. Conceptualization, methodology, formal analysis, 12. Al-Marhoon MS, Shareef O, Venkiteswaran KP, 2012,
investigation, supervision, writing - review and editing.
H. S. Conceptualization, methodology, resources, Complications and Outcomes of JJ Stenting of the Ureter
supervision, writing - review and editing, funding in Urological Practice: A Single-centre Experience. Arab J
acquisition. Urol, 10:372–7.
106 International Journal of Bioprinting (2022)–Volume 8, Issue 2