Page 114 - IJB-8-2
P. 114

3D-Printing-Assisted EADs for Preventing VUR through DJ Stents
           computational  simulation  was  conducted  for  forward   References
           and backward urine flows. Consequently, the difference
           in the cross-sectional pressure fields of the penta-shaped   1.   Pengfei S, Min J, Jie Y, et al., 2011, Use of Ureteral Stent
           EAD could expand the canopy membrane along the rib      in Extracorporeal Shock Wave Lithotripsy for Upper Urinary
           structures of the EAD. For the fabrication of the EADs, 3D   Calculi:  A  Systematic  Review  and  Meta-analysis.  J  Urol,
           printing and casting methods were utilized. The printed   186:1328–35.
           PLA mold and die were tailored to create four different      https://doi.org/10.1016/j.juro.2011.05.073
           umbrella shapes with flexible and biocompatible Ecoflex.
           Among  the  fabricated  devices,  the  penta-shaped  EAD   2.   Hübner WA, Plas EG, Trigo-Rocha F, et al., 1993, Drainage
           showed  the  best  anti-reflux  performance  compared  to   and  Reflux  Characteristics  of Antireflux  Ureteral  Double-J
           the other types. The maximum anti-reflux efficiency was   Stents. J Endourol, 7:497–9.
           observed when the EAD was attached near the bladder-     https://doi.org/10.1089/end.1993.7.497
           ureter junction, and an approximately 44% decrease in   3.   Dyer RB, Chen MY, Zagoria RJ, et al., 2002, Complications
           reflux was demonstrated in the ureter line using a voiding   of Ureteral Stent Placement. Radiographics, 22:1005–22.
           model. In addition, the anti-reflux efficiency did not show
           significant changes depending on the number of EADs      https://doi.org/10.1148/radiographics.22.5.g02se081005
           attached  to  the  DJ  stent.  Thus,  a  single  EAD  sufficed   4.   Irani J, Siquier J, Pirès C, et al., 1999, Symptom Characteristics
           to minimize reflux of urine with minimal discomfort to   and the Development of Tolerance with Time in Patients with
           patients. A disadvantage of the FDM-type 3D printer (i.e.,   Indwelling Double-pigtail Ureteric Stents. BJU Int, 84:276–9.
           rough  surface  with  grooved  patterns)  was  intentionally      https://doi.org/10.1046/j.1464-410x.1999.00154.x
           used  for  mechanically  robust  adhesion  between  the   5.   Auge BK, Preminger GM, 2002, Ureteral stents and their use
           EAD and DJ stent. Finally, a long-term soaking test in
           artificial urine with different pH values was performed   in endourology. Curr Opin Urol, 12:217–22.
           to  demonstrate  the  safety,  mechanical  durability,  and      https://doi.org/10.1097/00042307-200205000-00007
           chemical  stability  of  the  device  in  urine  for  at  least   6.   Sarier  M,  Demir  M,  Duman  I,  et al.,  2017,  Evaluation  of
           4 weeks. Although in vivo and parametric studies on the   Ureteral Stent Colonization in Live-Donor Renal Transplant
           length,  shape,  and  thickness  of  the  EAD  are  required   Recipients. Transplant Proc, 49:415–9.
           to  enhance  the  rectification  performance,  the  findings      https://doi.org/10.1016/j.transproceed.2017.01.004
           of this study support the use of 3D printing methods to
           manufacture  various  medical  devices  with  flexibility,   7.   Sarier M, Seyman D, Tekin S, et al., 2017, Comparision of
           biocompatibility,  mechanical  durability,  and  chemical   Ureteral Stent Colonization Between Deceased and Live Donor
           stability for urological applications.                  Renal Transplant Recipients. Transplant Proc, 49:2082–5.
                                                                   https://doi.org/10.1016/j.transproceed.2017.09.028
           Funding                                             8.   Kim  HH,  Kim  KW,  Choi  YH,  et al.,  2020,  Numerical

           This  work  was  supported  by  the  National  Research   Analysis  of  Urine  Flow  with  Multiple  Sizes  of  Double-J
           Foundation of Korea (NRF), funded by the Ministry of    Stents. Appl Sci, 10:4291.
           Science  and  ICT  of  the  Republic  of  Korea  (No.  NRF-     https://doi.org/10.3390/app10124291
           2021R1C1C1010836).
                                                               9.   Seymour H, Patel U, 2000, Ureteric Stenting-current Status.
           Conflict of interest                                    Semin Intervent Radiol, 17:351–65.
           The authors declare that there is no conflict of interest.     https://doi.org/10.1055/s-2000-13148
                                                               10.  Damiano R, Oliva A, Esposito C, et al., 2002, Early and Late
           Author contributions                                    Complications  of  Double  Pigtail  Ureteral  Stent.  Urol  Int,

           J.  L.  Conceptualization,  methodology,  formal  analysis,   69:136–40.
           investigation,  data  curation,  validation,  visualization,      https://doi.org/10.1159/000065563
           writing - original draft, writing - review and editing. J.   11.  Leibovici  D,  Cooper  A,  Lindner  A,  et  al.,  2005,  Ureteral
           S.  Conceptualization,  methodology,  investigation,  data   Stents:  Morbidity  and  Impact  on  Quality  of  Life.  Isr Med
           curation, validation, writing - review and editing. J. K.   Assoc J, 7:491–4.
           J.  Conceptualization,  methodology,  formal  analysis,   12.  Al-Marhoon  MS,  Shareef  O,  Venkiteswaran  KP,  2012,
           investigation, supervision, writing - review and editing.
           H.  S.  Conceptualization,  methodology,  resources,    Complications  and  Outcomes  of  JJ  Stenting  of  the  Ureter
           supervision,  writing  -  review  and  editing,  funding   in Urological Practice: A Single-centre Experience. Arab J
           acquisition.                                            Urol, 10:372–7.

           106                         International Journal of Bioprinting (2022)–Volume 8, Issue 2
   109   110   111   112   113   114   115   116   117   118   119