Page 196 - AJWEP-22-6
P. 196

Tsankov, et al.




                                  Energy   performance   indicators (BDS   EN 13201:2016)         D E ,   D P , W/  kWh/  (lx.m 2 )  m 2 .г  0.833  0.016






                                          R EI ≥0.30  Surround   ratio (R EI )  0.57





                                          f TI  ≤15%  Threshold   increment   (glare   index; f TI ),   %  15
                               Table 5. Achieved lighting performance indicators for a sample street of class M4 in the town of Pavlikeni


                                    13201:2016) Standard lighting parameters for class M4 (BDS EN   U l  ≥0.60 Achieved lighting performance indicators (with maintenance   factor=0.81)  Longitudinal   uniformity   (U l )  0.60







                                          U o  ≥0.40  Overall   uniformity   (U o )  0.51




                                          L m  ≥0.75   cd/m 2  Average   luminance   (L ave ),   cd/m 2  0.83








                                  Geometric   configuration  Roadway   •    distribution   width: 8 m  Number of   •    traffic lanes: 2  Reflective road   •    surface type: R3  Pole spacing:   •    30 m  Luminaire   •    arrangement:   one-sided  Mounting   •    height: 6.2 m  Type 1  • Tilt angle: 15°  • Overhang: 0.5 m  • Section length:   1,020 m








                                  Street: “St. St. Cyril and Methodius”  Town: Pavlikeni  Lighting class: M4 LED street luminaire parameters used in the   lighting calculations  Light   Efficacy   Luminous   (κ),   flux (Ф),   type  lm/W  lm  145.6  7,282  Abbreviation: LED: Light-emitting diode.

















                                                Electric   power  (P), W  50






                Volume 22 Issue 6 (2025)                       190                           doi: 10.36922/AJWEP025310242