Page 97 - ARNM-2-3
P. 97
Advances in Radiotherapy
& Nuclear Medicine Radiotherapy with neutron/gamma tubes
ray production before being employed for therapeutic 3. Martellini M, Sarotto M, Leung KN, Gherardi G. A compact
uses. The mini neutron/gamma-ray tube system can neutron generator for the Niort treatment of severe solid
be conveniently located in a clinical facility or inside cancers. Med Res Arch. 2023;11(3).
the operational room of a hospital. If neutron/gamma doi: 10.18103/mra.v11i3.3799
radiotherapy is proven successful in removing all common 4. Persuad A, Kwan JW, Leitner M, et al. A tandem-based
types of tumors, it may become a standard therapeutic tool compact dual-energy gamma generator. Rev Sci Instrum.
for cancer treatment. 2010;81:02B904.
Acknowledgments doi: 10.1063/1.3258028
Fruitful discussions with Maurizio Martellini and members 5. Leung KN. Production of H- ions by thermal desorption
process. AIP Adv. 2023;13:075123.
of the Theranosti Centre (Milan, Italy) and the technical
support by C&E Enterprises are deeply acknowledged. doi: 10.1063/5.0162487
6. Leung KN. New mini neutron tubes with multiple
Funding applications. J Nucl Eng. 2024;5:197-208.
This work is supported by Berkion Technology’s internal doi: 10.3390/jne5030014
funding. This work is supported by Berkion Technology’s 7. Leung KN. New compact neutron generator system for
internal funding. The authors are currently affiliated with multiple applications. Nucl Technol. 2020;206:1607-1614.
Berkion Technology, which was involved in designing and
conducting the study. 8. National Research Council. Radiation Source Use and
Replacement: Abbreviated Version. Washington, DC: The
Conflict of interest National Academies Press; 2008.
doi: 10.17226/11976
The authors are currently affiliated with Berkion
Technology. However, the authors declared that they 9. Csikai J, editor. CRC Handbook of Fast Neutron Generator.
have no known competing financial interests or personal Vol. 1. Boca Raton, Florida: CRC Press Inc.; 1987.
relationships that could have influenced the work reported 10. Bin J, Obst-Huebl I, Mao JH, et al. A new platform for ultra-
in this paper. high dose rate radiobiological research using the BELLA PW
laser proton beamline. Sci Rep Nat Portfolio. 2022;12:1484.
Author contributions doi: 10.1038/s41598-022-05181-3
Conceptualization: All authors 11. Leung KN, Leung JK, Melville G. Feasibility study on medical
Writing – original draft: Ka-Ngo Leung isotope production using a compact neutron generator. Appl
Writing – review & editing: James K. Leung Radiat Isot. 2018;137C:23-27.
Ethics approval and consent to participate doi: 10.1016/j.apradiso.2018.02.026
12. Lee CL, Zhou XL. Thick target yields for the 7Li(p,n)7Be
Not applicable. reaction near threshold. Nucl Instrum Methods Phys Res B.
Consent for publication 1999;152:1-11.
13. Tanaka K, Kobayashi T, Sakurai Y, Nakagawa Y, Ishikawa M,
Not applicable. Hoshi M. Irradiation characteristics of BNCT using Near-
Threshold Li(p,n) Be direct neutrons: Application to intra-
7
7
Availability of data operative BNCT for malignant brain tumors. Phys Med Biol.
Not applicable. 2002;47:3011-3032.
doi: 10.1088/0031-9155/47/16/315
References
14. Sauerwein WAG, Wittig A, Moss R, Nakagawa Y, editors.
1. Macomber MW, Tarabadkar ES, Mayr NA, et al. Neutron Neutron Capture Therapy. Berlin: Springer-Heidelberg;
radiation therapy for treatment of refractory merkel cell 2012.
carcinoma. Int J Part Ther. 2017;3:485-491.
15. Durisi E, Zanini A, Manfredotti C, et al. Design of an
doi: 10.14338/IJPT-17-0003.1 epithermal column for BNCT based on D-D fusion neutron
2. Krull A, Schwarz R, Brackrock S, et al. Neutron therapy facility. Nucl Instrum Methods Phys Res A. 2007;574:363-369.
in malignant salivary gland tumors: Results at European 16. Wang S, Blaha C, Santos R, et al. Synthesis and initial
Centers. Recent Results Cancer Res. 1998;150:88-99. biological evaluation of boron-containing prostate-specific
Volume 2 Issue 3 (2024) 7 doi: 10.36922/arnm.3920